A Method to Determine Doublet Photopeak Area 137Cs and 214Bi, in NORM Soil by NaI-detector
DOI:
https://doi.org/10.14331/ijfps.2015.330083Keywords:
Doublet peak area, Environmental radioactive sources, NaI scintillation spectroscopy, Cesium-137Abstract
Due to the poor resolution of (76 mm×76 mm) NaI scintillation detector, ~7.5% for 137Cs peak (661.5 keV), a mutual spectral interferences of environmental samples between 137Cs and 214Bi (609 keV) in the decay series of uranium peaks, is a serious problem. This overlapped problem appears in low level sample spectrum causes overestimation of the specific activity of both nuclides. The main purpose of this work is to resolve this problem and to present a methodology to correct the activity concentrations of 137Cs by NaI(Tl) spectroscopy. In Duhok governorate of Iraq, as a real NORM case, the accumulation of 137Cs is significant brought by west-north wind and precipitation in the years following nuclear weapons testing and Chernobyl accident in 1986. The developed correlations for any ratio of the measured areas of 214Bi and 137Cs overcome the overestimation and show very good results. The method is approved by comparing the relative error of the measured and corrected activity of Bi with that measured Pb. The maximum, minimum and average relative errors decreased from 40%, 7.3% and 19.4% to 6.1%, -6.5% and 0.6% respectively.
Downloads
References
Abdullah, K., & Ahmed, M. (2012). Environmental and Radiological Pollution in Creek Sediment and Water from Duhok, Iraq. Nucleus, 49(1), 49-59.
Abdullah, K., & Ramadhan, R. (2011). Determination of gamma-emitting radionuclides in Duhok city, Iraq. Nucleus, 48(4), 295-300.
Fairlie, I., & Sumner, D. (2006). The other report on Chernobyl (TORCH): Altner Combecher Foundation, Berlin.
Froehlich, K. (2009). Environmental radionuclides: Tracers and timers of terrestrial processes (Vol. 16): Elsevier.
Gilmore, G. (2011). Practical gamma-ray spectroscopy: John Wiley & Sons.
Hurtado, S., García-León, M., & García-Tenorio, R. (2006). A revision of energy and resolution calibration method of Ge detectors. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 564(1), 295-299.
MCD-2. (2002). Dual Input Multi-scalar/Multichannel Analyzer user Manual, FAST ComTec Communication Technology GmbH, D-82041 Obreaching, Germany . http://www.fastcomtec.com.
Poschl, M., & Nollet, L. M. (2006). Radionuclide concentrations in food and the environment: CRC Press.
Singh, S., Rani, A., & Mahajan, R. K. (2005). 226 Ra, 232 Th and 40 K analysis in soil samples from some areas of Punjab and Himachal Pradesh, India using gamma ray spectrometry. Radiation measurements, 39(4), 431-439