<?xml version="1.0" encoding="UTF-8"?>
<doi_batch version="4.4.2" xmlns="http://www.crossref.org/schema/4.4.2" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xmlns:jats="http://www.ncbi.nlm.nih.gov/JATS1" xsi:schemaLocation="http://www.crossref.org/schema/4.4.2 http://www.crossref.org/schema/deposit/crossref4.4.2.xsd">
<head>
  <doi_batch_id>3b238e271973795cd62-275</doi_batch_id>
  <timestamp>20250604154630578</timestamp>
  <depositor>
    <depositor_name>funda:funda</depositor_name>
    <email_address>fundamentalJournals@gmail.com</email_address>
  </depositor>
  <registrant>WEB-FORM</registrant>
</head>
<body>
  <journal>
    <journal_metadata>
  <full_title>International Journal of Fundamental Physical Sciences</full_title>
  <abbrev_title>IJFPS</abbrev_title>
  <issn media_type='electronic'>22318186</issn>
</journal_metadata>
<journal_issue>
  <publication_date media_type='online'>
    <month>03</month>
    <year>2012</year>
  </publication_date>
  <journal_volume>
    <volume>2</volume>
  </journal_volume>
  <issue>1</issue>
</journal_issue><!-- ============== -->
<journal_article publication_type='full_text'>
  <titles>
  <title>Assessment of Medical X-Ray Radiographic Screen-Films in Different Spatial Frequencies According To Detective Quantum Efficiency Computation</title>
  </titles>
  <contributors>
    <organization sequence='first' contributor_role='author'>Department of Physics,Faculty of Science, University Teknologi Malaysia,81300 Johor, Malaysia</organization>
    <person_name sequence='first' contributor_role='author'>
     <given_name>Mohammad Hassan</given_name>
      <surname>Khanmirzaei</surname>
    </person_name>
    <person_name sequence='additional' contributor_role='author'>
      <given_name>Wan Muhamad Saridan Wan</given_name>
      <surname>Hassan</surname>
    </person_name>
   <organization sequence='additional' contributor_role='author'>Department of Physics,Faculty of Science, University Teknologi Malaysia,81300 Johor, Malaysia</organization>
  </contributors>
  <jats:abstract xml:lang='en'>
    <jats:p>In medical imaging, to make better images there are some measures such as detective quantum efficiency (DQE) and noise equivalent quanta (NEQ) used to evaluate the image quality of each imaging system. Detective quantum efficiency (DQE) is one of the important measures in the assessment of image quality and detector performance. DQE of two types of screen-films namely Lanex Regular/T-Mat G/RA and Lanex Regular/T-Mat L/RA were determined using MTF and NPS data, separately. Moreover, gamma was calculated from characteristic curves for each screen film and photon flounce was estimated using published literature. DQE of the screen-films were computed for three optical densities 0.7, 1.0 and 1.4. The results show Lanex Regular/T-Mat G has better DQE than Lanex Regular/T-Mat L -especially at low frequency with higher contrast for diagnostic radiology purposes.</jats:p>
  </jats:abstract>
<publication_date media_type='online'>
    <month>03</month>
    <year>2012</year>
  </publication_date>  <pages>
  <first_page>9</first_page>
  <last_page>11</last_page>
  </pages>
  <doi_data>
  <doi>10.14331/ijfps.2012.330026</doi>
  <resource>https://www.fundamentaljournals.com/index.php/ijfps/article/view/27</resource>
  </doi_data>