Authors: S. Behrouzinia, M. Aghababaeinezhad, K. Khorasani, B. Sajad, D. Salehinia, Z. Dehghani Mahmoodabadi, M. Sabaghi
Affiliations: Laser and Optics Research School, Nuclear Science and Technology Research School, Atomic Energy Organization of Iran, Tehran, Iran, Physics Department, Alzahra University, Tehran, Iran
Emails: sbehrouzi@aeoi.org.ir
Journal: International Journal of Fundamental Physical Sciences (IJFPS)
Volume: 2, Issue: 1, Pages: 6-8, Date: March, 2012
ISSN: 2231-8186
DOI: https://doi.org/10.14331/ijfps.2012.330025
Two gold vapor laser tubes with different lengths of 60 and 75 cm and identical diameter of 16 mm were used to investigate the behavior of inverse voltage on thyratron’s anode in the excitation circuit, versus operational parameters such as buffer gas pressure and electrical input voltage. It was shown that, the inverse voltage on thyratron’s anode decreases with increasing of the buffer gas pressure and so electrical input voltage, individually. By optimization of these operational parameters, the lifetime of thyratron will be increased.
Thyratron, Inverse voltage, breakdown voltage, gold vapour laser